Overhead Service

Please make a note of verticle clearance requirements for each tpe of service. Permanent service poles are the property of Lane Electric. Lane Electric will install and maintain the poles and guywires.
Overhead Service

Overhead Service Attachment

Notes:

  1. LEC will furnish the meter, service drop conductor and service attachment to the conduit mast. The Cooperative will connect the member’s conductors to the Cooperative’s service drop.
  2. The consumer will furnish the service entrance conduit, conductor and meterbase in accordance to code requirements. A minimum of 18” member conductor must extend from the weatherhead.
  3. A strong enough service mast must be mounted on the side nearest LEC’s distribution pole. A clear path must exist between service drop attachment and pole. Avoid service wire overhang above roof, or provide code clearance.
  4. Energizing of Consumers service is contingent upon a State or City electrical inspection.
  5. See Exhibits A & B for details of clearance requirements.

Temporary Overhead Installation

Notes:

  1. Temporary pole should be located as specified by the Cooperative.
  2. Consumer shall supply temporary pole, meterbase, main disconnect, and grounds to N.E.C. construction code specifications.
  3. The Cooperative will provide maximum 30’ service drop and install meter.
  4. Energizing of consumer’s service is contingent upon an approved State or City electrical inspection.

Overhead Service With Underground Feeder

Notes:

  1. All electric connections, equipment, and equipment grounds shall comply with the National Electric Safety Code.
  2. The consumer shall furnish and maintain all conduit, conduit straps, grounds, disconnects, meterbase, and all conductors beyond LEC’s point of delivery.
  3. LEC shall furnish and maintain the meter, service drop, pole, guy wire, and anchor.
  4. Energizing of consumers service is contingent upon an approved State or City electrical inspection.

Overhead Service With Overhead Feeder

Notes:

All electric connections, equipment, and equipment grounds shall comply with the National Electric Safety Codes.

The consumer shall furnish and maintain all conduit, conduit straps, grounds, disconnects, meterbase, and all conductors beyond LEC’s point of delivery.

LEC shall furnish and maintain the meter, service drop, pole, guy wire, and anchor.

Energizing of consumer’s service is contingent upon an approved State or City electrical inspection.